Dichroic Filter
In the high frequency community there has been an increasing interest in so called frequency selective surfaces (FSS). These materials are built as large array of single unit cells. On the microscopic level, such a unit cell consists for example of a metal structure and air around. On the macroscopic level, they overall act as frequency selective material due to their microscopic resonances. In Figure 1 the dichroic filter [1] as an example for frequency selective surfaces is shown.
Figure 1: Picture of the dichroic filter structure [1].
When simulating such structures, there is no need to simulate the whole array of unit cells, which would be time and memory consuming. Instead it is advantageous to simulate a single unit cell and use adequate boundary conditions. The dichroic filter shown above can be simulated by the unit cell depicted in figure 2 (left), where the gold areas are sufficiently accurate represented by PEC material (grey). The whole array is modeled by the magnetic and electric boundary conditions, which mirror the structure in x and y direction to infinity.
Figure 2: Structure prepared for simulation with CST MWS (left) and with appropriate boundary conditions (right).
The results obtained with CST MWS are in good agreement with the measurements. The first passband (center frequency 1300 GHz) and second passband (center frequency 1750 GHz), which indicate the filter behaviour, are shown in the measurements and simulation results as well.
Figure 3: Simulated (left) and measured (right) s-parameter results [1].
Within the MWS simulation also the electric and magnetic field pattern is obtained. Figure 5 shows the field plots, of the two modes which are able to propagate.
Figure 4: Field plots of the electric field at 1300 GHz (upper) and at 1700 GHz (lower). The frequency of 1300 GHz is located in the first passband, while 1700 GHz is located in the second passband.
References:
[1] C. Winnewisser, F. Lewen, J. Weinzierl, H. Helm, "Transmission features of frequency-selective components in the far infrared determined by terahertz time-domain spectroscopy.", Applied Optics, Vol. 38, No. 18, pp. 3961-3967, 1999.
CST Article "Dichroic Filter"
last modified 7. Jan 2009 5:59
printed 7. Jan 2009 5:59, Article ID 121
URL:
All rights reserved.
Without prior written permission of CST, no part of this publication may be
reproduced by any method, be stored or transferred into an electronic data processing system, neither mechanical or by any other method.
Article ID: 121
Last modified: 7. Jan 2009 5:59
Other Articles
This article examines the modelling of lightning strikes using CST MICROWAVE STUDIO® (CST MWS). The surface current distribution due to a double-exponential form lightning strike on the nose of an airplane is calculated by way of example.
Read full article..
The simulation of a gas insulated switch at 50 Hz is simulated with the low frequency solver in CST EM STUDIO™ (CST EMS). A Pro/E® model is imported, appropriate three-phased sources defined and a simulation performed to obtain the current distributions in the three phase conductors.
Read full article..
This structure for mobile communication in LTCC technology combines a diplexer for the GSM and DCS frequency bands with a low pass filter for each band.
Read full article..
New, compact configurations for RF/microwave bandstop and lowpasss filters are presented. Compact footprints are achieved by folding the transmission lines in a microstrip platform. The effect of mutual coupling between the transmission lines, curved line sections, interconnecting lengths of the sections are taken into account to obtain the network parameters for the folded line filters. The folded line filters have practical dimensions for a wide range of electrical specifications, making physical implementation realizable. The filter designs have been validated by using full wave 3D EM simulation using CST MICROWAVE STUDIO®, as well as by comparison with the measurements. The new designs presented should prove useful for a host of embedded passive and RFIC applications in the 1-10 GHz range.
Read full article..
In this article the simulation of parasitic effects in a standard IC package is shown. The transient simulator in CST MICROWAVE STUDIO® (CST MWS) offers the advantage, that effects such as crosstalk and signal delay can be investigated in both time and frequency domain. Additionally, the simulation results can be used to generate an equivalent RLC network model that has the same S-Parameters as the 3D EM simulation but can be included in the overal circuit simulation of the logical parts of the IC.
Read full article..