Computer Simulation Technology
 
CST

Magnetostatic simulation of a magnetic injection valve

CST EM STUDIO™ (CST EMS) can be used for the simulation of actuators such as a magnetic injection valve as shown in figure 1. This device was entirely constructed using the powerful user interface in CST EMS. The coil was created by defining a cross-section and sweep path to form a solenoidal shape. Alternatively, more complex devices may be imported using the comprehensive CAD Import facilities in the CST DESIGN ENVIRONMENT™.  Of interest is the flux density distribution in the device as well as derived quantities such as the force on the valve armature as a function of coil current and armature-housing gap. The non-linear magnetostatic solver is applied to the simulation of the valve, utilising either a hexahedral or tetrahedral mesh. In this particular case, the hexahedral mesh is an excellent choice since it not only provides equally accurate results but also allows the consistent control of the mesh at critical parts of the geometry, such as the air gaps, during the parameterisation process.

 


Geometry of the magnetic injection valve with excitation coil.
Figure 1: Geometry of the magnetic injection valve with excitation coil.

Figure 2 shows a more detailed breakdown of the geometry of the magnetic injection valve along with the magnetic materials taken for the simulation. The model was created using polygons which have been rotationally swept over 360 degrees and the coil (shown only in figure 1)  was constructed using the coil tool in CST EMS. Appropriate symmetry conditions have been applied to reduce the simulation volume by a quarter. A parameter sweep is set up to sweep the current Ampere Turns in the coils  in order to obtain the armature force versus gap characteristic as a function of coil Ampere-Turns.

For the correct modelling of this device, the non-linear magentic characteristics of the materials should be taken into account. The BH curves for each material were taken from actual material measurements.


Cut-away construction and magnetic materials of the injection valve.
Figure 2: Cut-away construction and magnetic materials of the injection valve.

Figure 3 shows the absolute flux density in the valve for the case where the air gap is 0.3 mm. Other quantities automatically available include the H-Field and the permeability distribution. Further secondary quantities such as system energy and force are also delivered by the solver. Post-processing templates can also be defined to obtain other user-defined secondary quantities.


Vector and contour plot of the Absolute magnetic flux density on a central cut-plane through the valve with a gap of 0.3 mm.
Figure 3: Vector and contour plot of the Absolute magnetic flux density on a central cut-plane through the valve with a gap of 0.3 mm.

The force on the armature is an important characteristic for this valve, namely, its variation with armature gap size and applied coil current. The force is automatically calculated as a post-processing step, the results of which can be captured by the post-processing templates and displayed as a familly of curves as shown in figure 4. In the figure, the armature gap is shown by two red points. The number of mesh lines in the gap is defined in terms of the gap parameter to ensure that the mesh is adequately refined in the gap regardless of the gap width. This ensures a consistent result throughout the parameterisation process. 


Armature force as function of parameterised armature gap and coil Ampere-Turns. The mesh density in the gap is refined as a function of the gap width.
Figure 4: Armature force as function of parameterised armature gap and coil Ampere-Turns. The mesh density in the gap is refined as a function of the gap width.

This article has demonstrated the modelling and paramterisation of a magnetic valve using CST EMS and its parameterisation facilities. This model was entirely created using the user interface of CST EMS. More complex geometries can be imported and parameterised using the modification and parameterised facilities. The force can be derived effortlessly for a range of parameters to allow the engineer to investigate the effect of the model geometry and excitation on the behaviour of the device.


CST Article "Magnetostatic simulation of a magnetic injection valve"
last modified 2. May 2007 6:42
printed 7. Jan 2009 4:19, Article ID 343
URL:

All rights reserved.
Without prior written permission of CST, no part of this publication may be reproduced by any method, be stored or transferred into an electronic data processing system, neither mechanical or by any other method.

Other Articles

Transmission Line Noise Source Simulation with CST MICROWAVE STUDIO®

Transmission Line Noise Source Simulation with CST MICROWAVE STUDIO®
This article demonstrates the simulatenous excitation of arbitrary waveforms at a number of different ports. A noise source in the form of a loop circuit is place above an IC package and the influence of the noise source on the transmission of differential signals in the IC feed tranmssion lines is investigated. Two frequency ranges were simulated, 1-10 GHz and 1-20 GHz. The simulations were carried out using the simultaneous excitation feature in CST MICROWAVE STUDIO® (CST MWS). Read full article..

A Small, Efficient, Linear-polarized Omni-directional Antenna

A Small, Efficient, Linear-polarized Omni-directional Antenna
Nearly full-sized performance from a spherical coil only 1/6th as long in the E-plane normal direction as a half-wave dipole antenna. Read full article..

Optical Ring-Coupler Simulation using CST MICROWAVE STUDIO®

Optical Ring-Coupler Simulation using CST MICROWAVE STUDIO®
CST MICROWAVE STUDIO® can be succesfully applied to optical problems as shown in this example of an optical ring coupler solved up to 250 THz. Read full article..

CMOS VCSEL Driver Design using CST MICROWAVE STUDIO® and Agilent ADS

CMOS VCSEL Driver Design using CST MICROWAVE STUDIO® and Agilent ADS
CST MICROWAVE STUDIO® and Agilent ADS have been successfully employed in this OEIC driver design - an example of a high speed analog/broadband IC application.The package model was imported from Agilent momentum and the model was simulated upto a 100 GHz in CST MWS.The resulting eye diagrams of the driver design from CST MWS are compared with those from Agilent momentum and other test cases. Read full article..

RFID Transponder operating at 13.56 MHz

RFID Transponder operating at 13.56 MHz
Radio Frequency Identification Systems (RF-ID) are widely used and are thus one of the fastest growing sectors of todays radio industry, allowing advanced solutions for a variety of applications in the area of authentication, ticketing, access control, supply management, etc. One of the most common band allocated to RFID systems is 13.56 MHz. For this application example operating at this particular frequency band we have chosen a transponder inlay which was created using the ACIS based solid modeler of CST MICROWAVE STUDIO® The frequency domain solver of CST MICROWAVE STUDIO® has been applied to accurately predict the input impedance, followed by a lumped element based equivelent circuit derivation to describe the impedance versus frequency. Read full article..

Back